SVE remediation technology uses vacuum blowers and vapor extraction wells to induce gas flow through the subsurface, collecting contaminated soil vapor, which is subsequently treated aboveground (Fig. 1)<ref>Hutzler, N.J., Murphy, B.E., Gierke, J.S., 1990. State of technology review: soil vapor extraction systems. U.S. Environmental Protection Agency, Risk Reduction Engineering Laboratory, Cincinnati, Ohio. EPA/600/S2-89/024. [http://www.environmentalrestoration.wiki/images/5/5a/EPA-1990-State_of_Tech_Rev-Soil_Vapor_Extraction_System.pdf Report pdf]</ref><ref>Pedersen, T.A., Curtis, J.T., 1991. Soil vapor extraction technology. Noyes Data Corporation, Park Ridge, New Jersey.</ref><ref>Noyes, R. 1994. Unit operations in environmental engineering. Noyes Publications, Park Ridge, New Jersey. [http://store.elsevier.com/Unit-Operations-in-Environmental-Engineering/Robert-Noyes/isbn-9780815513438/ ISBN: 978-0-8155-1343-8]</ref><ref>Stamnes, R., Blanchard, J., 1997. Engineering forum issue paper: soil vapor extraction implementation experiences. U.S. Environmental Protection Agency, Washington, D.C. EPA 540/F-95/030. [http://www.environmentalrestoration.wiki/images/4/4e/Stamnes-1997-Soil_Vapor_Extraction_Implementation_Experiences.pdf Report pdf]</ref><ref>Suthersan, S.S., 1999. Soil vapor extraction. In: Remediation Engineering Design Concepts. CRC Press, Suthersan, S.S., ed., Boca Raton, Florida. [https://www.crcpress.com/Remediation-Engineering-Design-Concepts/Suthersan/p/book/9781566701372 ISBN: 978-1-5667-0137-2]</ref><ref>Khan, F.I., Husain, T., Hejazi, R., 2004. An overview and analysis of site remediation technologies. Journal of Environmental Management, 71(2), 95-122. [http://dx.doi.org/10.1016/j.jenvman.2004.02.003 doi: 10.1016/j.jenvman.2004.02.003]</ref><ref>Damera, R., Bhandari, A., 2007. Physical treatment technologies. In: Remediation Technologies for Soils and Groundwater. Edited by A. Bhandari, R.Y. Surampalli, P. Champagne, S.K. Ong, R.D. Tyagi, I.M.C. Lo. American Society of Civil Engineers, Reston, Virginia. [http://dx.doi.org/10.1061/9780784408940.ch03 doi: 10.1061/9780784408940.ch03]</ref><ref name= "Brusseau2013"/>. The system can be implemented with standard wells and off-the-shelf equipment (blowers, instrumentation, vapor treatment, etc.). The vacuum extraction of soil gas induces gas flow through the vadose zone, increasing the rate of mass transfer from aqueous (soil moisture), non-aqueous (pure phase), and solid (soil) phases into the gas phase. Some systems only use soil gas extraction wells. Other systems also include air injection wells to help guide airflow through contaminated zones. Enhancements for improving SVE effectiveness can include directional drilling (to access under surface features that prevent vertical drilling or to align better with the contaminant distribution and/or subsurface features), pneumatic and hydraulic fracturing (to enhance subsurface airflow), and [[In Situ Thermal Remediation | thermal enhancement]] (e.g., hot air or steam injection to increase contaminant volatility)<ref>Frank, U., Barkley, N., 1995. Remediation of low permeability subsurface formations by fracturing enhancement of soil vapor extraction. Journal of Hazardous Materials, 40(2), 191-201. [http://dx.doi.org/10.1016/0304-3894(94)00069-s doi:10.1016/0304-3894(94)00069-S]</ref><ref>U.S. Environmental Protection Agency, 1997. Analysis of selected enhancements for soil vapor extraction. Office of Solid Waste and Emergency Response, Washington, D.C. EPA/542/R-97/007. [http://www.environmentalrestoration.wiki/images/4/48/EPA-1997-Analysis_of_Selected_Enhancements_for_SVE.pdf Report pdf]</ref><ref>Peng, S., Wang, N., Chen, J., 2013. Steam and air co-injection in removing residual TCE in unsaturated layered sandy porous media. Journal of Contaminant Hydrology, 153, 24-36. [http://dx.doi.org/10.1016/j.jconhyd.2013.07.002 doi: 10.1016/j.jconhyd.2013.07.002]</ref>. Passive SVE systems that rely on barometric pumping for soil gas extraction may also be employed<ref>Early, T., Borden, B., Heitkamp, M., Looney, B.B., Major, D., Waugh, W.J., Wein, G., Wiedemeier, T. Vangelas, K.M., Adams, K.M., Sink, C.H., 2006. Enhanced attenuation: a reference guide on approaches to increase the natural treatment capacity of a system. Washington Savannah River Company, Aiken, South Carolina. WSRC-STI-2006-00083, Rev.1. [http://www.environmentalrestoration.wiki/images/4/48/Early-2006-Enhanced_Attenuation-A_Ref_Guide_on_Approaches...natural_treatment_cap.pdf Report pdf]</ref><ref>Kamath, R., Adamson, D.T. , Newell, C.J., Vangelas, K.M., Looney, B.B., 2010. Passive soil vapor extraction. Savannah River National Laboratory, Aiken, South Carolina. SRNL-STI-2009-00571, Rev. 1. [http://www.environmentalrestoration.wiki/images/0/06/Kamath-2010-Passive_Soil_Vapor_Extraction-SRNL-STI-2009-00571.pdf Report pdf]</ref>. | SVE remediation technology uses vacuum blowers and vapor extraction wells to induce gas flow through the subsurface, collecting contaminated soil vapor, which is subsequently treated aboveground (Fig. 1)<ref>Hutzler, N.J., Murphy, B.E., Gierke, J.S., 1990. State of technology review: soil vapor extraction systems. U.S. Environmental Protection Agency, Risk Reduction Engineering Laboratory, Cincinnati, Ohio. EPA/600/S2-89/024. [http://www.environmentalrestoration.wiki/images/5/5a/EPA-1990-State_of_Tech_Rev-Soil_Vapor_Extraction_System.pdf Report pdf]</ref><ref>Pedersen, T.A., Curtis, J.T., 1991. Soil vapor extraction technology. Noyes Data Corporation, Park Ridge, New Jersey.</ref><ref>Noyes, R. 1994. Unit operations in environmental engineering. Noyes Publications, Park Ridge, New Jersey. [http://store.elsevier.com/Unit-Operations-in-Environmental-Engineering/Robert-Noyes/isbn-9780815513438/ ISBN: 978-0-8155-1343-8]</ref><ref>Stamnes, R., Blanchard, J., 1997. Engineering forum issue paper: soil vapor extraction implementation experiences. U.S. Environmental Protection Agency, Washington, D.C. EPA 540/F-95/030. [http://www.environmentalrestoration.wiki/images/4/4e/Stamnes-1997-Soil_Vapor_Extraction_Implementation_Experiences.pdf Report pdf]</ref><ref>Suthersan, S.S., 1999. Soil vapor extraction. In: Remediation Engineering Design Concepts. CRC Press, Suthersan, S.S., ed., Boca Raton, Florida. [https://www.crcpress.com/Remediation-Engineering-Design-Concepts/Suthersan/p/book/9781566701372 ISBN: 978-1-5667-0137-2]</ref><ref>Khan, F.I., Husain, T., Hejazi, R., 2004. An overview and analysis of site remediation technologies. Journal of Environmental Management, 71(2), 95-122. [http://dx.doi.org/10.1016/j.jenvman.2004.02.003 doi: 10.1016/j.jenvman.2004.02.003]</ref><ref>Damera, R., Bhandari, A., 2007. Physical treatment technologies. In: Remediation Technologies for Soils and Groundwater. Edited by A. Bhandari, R.Y. Surampalli, P. Champagne, S.K. Ong, R.D. Tyagi, I.M.C. Lo. American Society of Civil Engineers, Reston, Virginia. [http://dx.doi.org/10.1061/9780784408940.ch03 doi: 10.1061/9780784408940.ch03]</ref><ref name= "Brusseau2013"/>. The system can be implemented with standard wells and off-the-shelf equipment (blowers, instrumentation, vapor treatment, etc.). The vacuum extraction of soil gas induces gas flow through the vadose zone, increasing the rate of mass transfer from aqueous (soil moisture), non-aqueous (pure phase), and solid (soil) phases into the gas phase. Some systems only use soil gas extraction wells. Other systems also include air injection wells to help guide airflow through contaminated zones. Enhancements for improving SVE effectiveness can include directional drilling (to access under surface features that prevent vertical drilling or to align better with the contaminant distribution and/or subsurface features), pneumatic and hydraulic fracturing (to enhance subsurface airflow), and [[In Situ Thermal Remediation | thermal enhancement]] (e.g., hot air or steam injection to increase contaminant volatility)<ref>Frank, U., Barkley, N., 1995. Remediation of low permeability subsurface formations by fracturing enhancement of soil vapor extraction. Journal of Hazardous Materials, 40(2), 191-201. [http://dx.doi.org/10.1016/0304-3894(94)00069-s doi:10.1016/0304-3894(94)00069-S]</ref><ref>U.S. Environmental Protection Agency, 1997. Analysis of selected enhancements for soil vapor extraction. Office of Solid Waste and Emergency Response, Washington, D.C. EPA/542/R-97/007. [http://www.environmentalrestoration.wiki/images/4/48/EPA-1997-Analysis_of_Selected_Enhancements_for_SVE.pdf Report pdf]</ref><ref>Peng, S., Wang, N., Chen, J., 2013. Steam and air co-injection in removing residual TCE in unsaturated layered sandy porous media. Journal of Contaminant Hydrology, 153, 24-36. [http://dx.doi.org/10.1016/j.jconhyd.2013.07.002 doi: 10.1016/j.jconhyd.2013.07.002]</ref>. Passive SVE systems that rely on barometric pumping for soil gas extraction may also be employed<ref>Early, T., Borden, B., Heitkamp, M., Looney, B.B., Major, D., Waugh, W.J., Wein, G., Wiedemeier, T. Vangelas, K.M., Adams, K.M., Sink, C.H., 2006. Enhanced attenuation: a reference guide on approaches to increase the natural treatment capacity of a system. Washington Savannah River Company, Aiken, South Carolina. WSRC-STI-2006-00083, Rev.1. [http://www.environmentalrestoration.wiki/images/4/48/Early-2006-Enhanced_Attenuation-A_Ref_Guide_on_Approaches...natural_treatment_cap.pdf Report pdf]</ref><ref>Kamath, R., Adamson, D.T. , Newell, C.J., Vangelas, K.M., Looney, B.B., 2010. Passive soil vapor extraction. Savannah River National Laboratory, Aiken, South Carolina. SRNL-STI-2009-00571, Rev. 1. [http://www.environmentalrestoration.wiki/images/0/06/Kamath-2010-Passive_Soil_Vapor_Extraction-SRNL-STI-2009-00571.pdf Report pdf]</ref>. | ||
− | |||
The soil gas (vapor) that is extracted by the SVE system generally requires treatment prior to discharge back into the environment. The aboveground treatment is primarily for a gas stream, although condensation of liquid must be managed (and in some cases may specifically be desired). A variety of treatment techniques are available for aboveground treatment<ref>U.S. Environmental Protection Agency, 2006. Off-gas treatment technologies for soil vapor extraction systems: state of the practice. Office of Superfund Remediation and Technology Innovation, Washington, D.C. EPA/542/R-05/028. [http://www.environmentalrestoration.wiki/images/e/e0/EPA-2006-Off-Gas_Treament_Tech_for_SVE_Ssytems-542R05028.pdf Report pdf]</ref> including: | The soil gas (vapor) that is extracted by the SVE system generally requires treatment prior to discharge back into the environment. The aboveground treatment is primarily for a gas stream, although condensation of liquid must be managed (and in some cases may specifically be desired). A variety of treatment techniques are available for aboveground treatment<ref>U.S. Environmental Protection Agency, 2006. Off-gas treatment technologies for soil vapor extraction systems: state of the practice. Office of Superfund Remediation and Technology Innovation, Washington, D.C. EPA/542/R-05/028. [http://www.environmentalrestoration.wiki/images/e/e0/EPA-2006-Off-Gas_Treament_Tech_for_SVE_Ssytems-542R05028.pdf Report pdf]</ref> including: |
Revision as of 14:32, 27 April 2018
Soil vapor extraction (SVE) is a common and typically effective physical treatment process for remediation of volatile contaminants in vadose zone (unsaturated) soils. During SVE, contaminated soil gas is extracted from the vadose zone, treated, and then discharged to the atmosphere. SVE is most effective at sites where airflow can be induced through contaminated zones. SVE is a mature technology and has been applied in multiple configurations. Like other extraction-based technologies, SVE effectiveness typically diminishes over time as readily extracted contaminant mass is removed and mass transfer limitations begin to control the recovery of remaining contaminant mass.
Related Article(s):
CONTRIBUTOR(S): Michael Truex
Key Resource(s):
- Characterization and Remediation of Chlorinated Volatile Organic Contaminants in the Vadose Zone[1]
- Soil Vapor Extraction System Optimization, Transition, and Closure Guidance [2]
Introduction
SVE (also referred to as in situ soil venting or vacuum extraction) is a vadose zone remediation method for volatile contaminants[3]. SVE is based on mass transfer of contaminant from the solid (sorbed) and liquid (aqueous or non-aqueous) phases into the gas phase, followed by collection and extraction of the contaminated soil gas. Extracted contaminant mass in the gas phase (and any condensed liquid phase) is then treated in aboveground systems. SVE is most effective for contaminants with higher Henry's Law constants, including a range of chlorinated solvents and hydrocarbons. SVE is a well-demonstrated, mature remediation technology that has been identified by the U.S. Environmental Protection Agency (EPA) as a presumptive remedy[4][5][6].
SVE Configuration
SVE remediation technology uses vacuum blowers and vapor extraction wells to induce gas flow through the subsurface, collecting contaminated soil vapor, which is subsequently treated aboveground (Fig. 1)[7][8][9][10][11][12][13][1]. The system can be implemented with standard wells and off-the-shelf equipment (blowers, instrumentation, vapor treatment, etc.). The vacuum extraction of soil gas induces gas flow through the vadose zone, increasing the rate of mass transfer from aqueous (soil moisture), non-aqueous (pure phase), and solid (soil) phases into the gas phase. Some systems only use soil gas extraction wells. Other systems also include air injection wells to help guide airflow through contaminated zones. Enhancements for improving SVE effectiveness can include directional drilling (to access under surface features that prevent vertical drilling or to align better with the contaminant distribution and/or subsurface features), pneumatic and hydraulic fracturing (to enhance subsurface airflow), and thermal enhancement (e.g., hot air or steam injection to increase contaminant volatility)[14][15][16]. Passive SVE systems that rely on barometric pumping for soil gas extraction may also be employed[17][18].
The soil gas (vapor) that is extracted by the SVE system generally requires treatment prior to discharge back into the environment. The aboveground treatment is primarily for a gas stream, although condensation of liquid must be managed (and in some cases may specifically be desired). A variety of treatment techniques are available for aboveground treatment[19] including:
- Thermal destruction (e.g., direct flame thermal oxidation, catalytic oxidizers),
- Adsorption (e.g., granular activated carbon, zeolites, polymers),
- Biofiltration,
- Non-thermal plasma destruction,
- Photolytic/photocatalytic destruction,
- Membrane separation,
- Gas absorption, and
- Vapor condensation.
The most commonly applied aboveground treatment technologies are thermal oxidation and granular activated carbon adsorption. Selection of a particular aboveground treatment technology depends on the contaminant, concentrations in the extracted gas, throughput, and economic considerations.
SVE Effectiveness
The rate and extent of mass removal by SVE depends on a number of factors that influence contaminant mass transfer into the gas phase. SVE effectiveness is a function of the contaminant properties (e.g., Henry's Law constant, vapor pressure, boiling point, adsorption coefficient), temperature in the subsurface, vadose zone soil properties (e.g., soil grain size, soil moisture content, permeability, carbon content), subsurface heterogeneity, and the airflow driving force (applied pressure gradient). As an example, a highly volatile contaminant (such as trichloroethene) in a homogeneous sand with high permeability and low carbon content (i.e., low/negligible adsorption) will be readily treated with SVE. In contrast, a low vapor pressure contaminant like naphthalene would require a longer treatment time and/or SVE enhancements, especially if it were present in a heterogeneous vadose zone with one or more low-permeability layers. SVE effectiveness is also related to the ability to induce airflow through contaminated portions of the vadose zone. Airflow in porous media is affected by the amount of connected gas-filled porosity, which is a function of the total porosity and the moisture content. Because low permeability zones typically have higher water saturation, gas-filled porosity can be low and airflow is inhibited in those zones. The SVE mass removal rate can decline over time (e.g., observed as tailing on a mass removal curve) when contaminants are present in zones with lower airflow (i.e., low-permeability zones or zones of high moisture content) and/or lower volatility (or higher adsorption). Recent work[20][21] has investigated layering and low permeability zones in the subsurface to understand how they affect SVE operations.
Design, Optimization, Performance, Assessment, and Closure
Implementation of SVE involves the following elements: system design, operation, optimization, performance assessment, and closure. Several guidance documents provide information on these implementation aspects. EPA and U.S. Army Corps of Engineers (USACE) guidance documents[22][23][24] establish an overall framework for design, operation, optimization, and closure of a SVE system. The Air Force Center for Engineering and the Environment (AFCEE) guidance[25] presents actions and considerations for SVE system optimization, but has limited information related to approaches for SVE closure and meeting remediation goals. As time goes on, it is typical for a SVE system to exhibit a diminishing rate of contaminant extraction due to mass transfer limitations for removal of contaminant mass. Performance assessment is a key aspect to provide input for decisions about whether the system should be optimized, terminated, or transitioned to another technology to replace or augment SVE. Guidance from the Pacific Northwest National Laboratory (PNNL)[2] supplements the aforementioned documents by discussing specific actions and decisions related to SVE optimization, transition, and/or closure. Assessment of rebound and mass flux[2][26][27] provide approaches to evaluate system performance and obtain information on which to base decisions.
References
- ^ 1.0 1.1 Brusseau, M.L., Carroll, K.C., Truex, M.J., Becker, D.J., 2013. Characterization and remediation of chlorinated volatile organic contaminants in the vadose zone. Vadose Zone Journal, 12(4). doi:10.2136/vzj2012.0137
- ^ 2.0 2.1 2.2 Truex, M.J., Becker, D., Simon, M.A., Oostrom, M., Rice, A.K., Johnson, C.D., 2013. Soil vapor extraction system optimization, transition, and closure guidance (No. PNNL-21843). Pacific Northwest National Laboratory (PNNL), Richland, WA. Report pdf
- ^ U.S. Environmental Protection Agency, 2012. A citizen’s guide to soil vapor extraction and air sparging. Office of Solid Waste and Emergency Response, Washington, D.C. EPA/542/F-2/018. Report pdf
- ^ U.S. Environmental Protection Agency, 1993. Presumptive Remedies: Site characterization and technology selection for CERCLA sites with volatile organic compounds in soils. Office of Solid Waste and Emergency Response, Washington, D.C. EPA/540/F-93/048. Report pdf
- ^ U.S. Environmental Protection Agency (USEPA), 1996. User's guide to the VOCs in soils presumptive remedy. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Washington, D.C. EPA/540/F-96/008. Report pdf
- ^ U.S. Environmental Protection Agency, 2011. Presumptive remedies: policy and procedures. U.S. Environmental Protection Agency, Office of Solid Waste and Emergency Response, Washington, D.C. US EPA Superfund site
- ^ Hutzler, N.J., Murphy, B.E., Gierke, J.S., 1990. State of technology review: soil vapor extraction systems. U.S. Environmental Protection Agency, Risk Reduction Engineering Laboratory, Cincinnati, Ohio. EPA/600/S2-89/024. Report pdf
- ^ Pedersen, T.A., Curtis, J.T., 1991. Soil vapor extraction technology. Noyes Data Corporation, Park Ridge, New Jersey.
- ^ Noyes, R. 1994. Unit operations in environmental engineering. Noyes Publications, Park Ridge, New Jersey. ISBN: 978-0-8155-1343-8
- ^ Stamnes, R., Blanchard, J., 1997. Engineering forum issue paper: soil vapor extraction implementation experiences. U.S. Environmental Protection Agency, Washington, D.C. EPA 540/F-95/030. Report pdf
- ^ Suthersan, S.S., 1999. Soil vapor extraction. In: Remediation Engineering Design Concepts. CRC Press, Suthersan, S.S., ed., Boca Raton, Florida. ISBN: 978-1-5667-0137-2
- ^ Khan, F.I., Husain, T., Hejazi, R., 2004. An overview and analysis of site remediation technologies. Journal of Environmental Management, 71(2), 95-122. doi: 10.1016/j.jenvman.2004.02.003
- ^ Damera, R., Bhandari, A., 2007. Physical treatment technologies. In: Remediation Technologies for Soils and Groundwater. Edited by A. Bhandari, R.Y. Surampalli, P. Champagne, S.K. Ong, R.D. Tyagi, I.M.C. Lo. American Society of Civil Engineers, Reston, Virginia. doi: 10.1061/9780784408940.ch03
- ^ Frank, U., Barkley, N., 1995. Remediation of low permeability subsurface formations by fracturing enhancement of soil vapor extraction. Journal of Hazardous Materials, 40(2), 191-201. doi:10.1016/0304-3894(94)00069-S
- ^ U.S. Environmental Protection Agency, 1997. Analysis of selected enhancements for soil vapor extraction. Office of Solid Waste and Emergency Response, Washington, D.C. EPA/542/R-97/007. Report pdf
- ^ Peng, S., Wang, N., Chen, J., 2013. Steam and air co-injection in removing residual TCE in unsaturated layered sandy porous media. Journal of Contaminant Hydrology, 153, 24-36. doi: 10.1016/j.jconhyd.2013.07.002
- ^ Early, T., Borden, B., Heitkamp, M., Looney, B.B., Major, D., Waugh, W.J., Wein, G., Wiedemeier, T. Vangelas, K.M., Adams, K.M., Sink, C.H., 2006. Enhanced attenuation: a reference guide on approaches to increase the natural treatment capacity of a system. Washington Savannah River Company, Aiken, South Carolina. WSRC-STI-2006-00083, Rev.1. Report pdf
- ^ Kamath, R., Adamson, D.T. , Newell, C.J., Vangelas, K.M., Looney, B.B., 2010. Passive soil vapor extraction. Savannah River National Laboratory, Aiken, South Carolina. SRNL-STI-2009-00571, Rev. 1. Report pdf
- ^ U.S. Environmental Protection Agency, 2006. Off-gas treatment technologies for soil vapor extraction systems: state of the practice. Office of Superfund Remediation and Technology Innovation, Washington, D.C. EPA/542/R-05/028. Report pdf
- ^ Switzer, C., Kosson, D.S., 2007. Soil vapor extraction performance in layered vadose zone materials. Vadose Zone Journal, 6(2), 397-405. doi: 10.2136/vzj2005.0131
- ^ Oostrom, M., Rockhold, M.L., Thorne, P.D., Truex, M.J., Last, G.V., Rohay, V.J., 2007. Carbon tetrachloride flow and transport in the subsurface of the 216-Z-9 trench at the Hanford Site. Vadose Zone Journal, 6(4), 971-984. doi: 10.2136/vzj2006.0166
- ^ DiGiulio, D.C., Varadhan, R., 2001. Development of recommendations and methods to support assessment of soil venting performance and closure. U.S. Environmental Protection Agency, EPA/600/R-01/070. Report pdf
- ^ U.S. Environmental Protection Agency, 2004. How to evaluate alternative cleanup technologies for underground storage tank sites. Office of Solid Waste and Emergency Response, Washington, D.C. EPA/510/R-04/002. Report pdf
- ^ U. S. Army Corps of Engineers, 2002. Soil vapor extraction and bioventing. EM 1110-1-4001. Washington, D.C. Report pdf
- ^ United States Air Force Environmental Restoration Program (AFCEE), 2001. Guidance on soil vapor extraction optimization. Brooks Air Force Base, Texas. Report pdf
- ^ Switzer, C., Slagle, T., Hunter, D., Kosson, D.S., 2004. Use of rebound testing for evaluation of soil vapor extraction performance at the savannah river site. Ground Water Monitoring Remediation, 24(4), 106-117. doi: 10.1111/j.1745-6592.2004.tb01308.x
- ^ Brusseau, M.L., Rohay, V., Truex, M.J., 2010. Analysis of soil vapor extraction data to evaluate mass-transfer constraints and estimate source-zone mass flux. Ground Water Monitoring Remediation, 30(3), 57-64. doi: 10.1111/j.1745-6592.2010.01286.x
See Also