− | Thermal Conduction Heating (TCH) is based on simple heating by [[wikipedia: Thermal conduction | thermal conduction]] in combination with fluid extraction. Elevated subsurface temperatures mobilize contaminants for extraction. TCH is an effective and predictable solution for organic source zones and can be combined with less aggressive methods for complete site and plume restoration (e.g., see [[Thermal Remediation - Combined Remedies]]).
| + | #REDIRECT[[Thermal Conduction Heating (TCH)]] |
− | | |
− | <div style="float:right;margin:0 0 2em 2em;">__TOC__</div>
| |
− | | |
− | '''Related Article(s)''':
| |
− | | |
− | *[[Thermal Remediation]]
| |
− | *[[Thermal Remediation - Steam]]
| |
− | *[[Thermal Remediation - Electrical Resistance Heating]]
| |
− | *[[Thermal Remediation - Combined Remedies]]
| |
− | | |
− | | |
− | '''CONTRIBUTOR(S):''' [[Dr. Gorm Heron]]
| |
− | | |
− | '''Key Resource(s)''':
| |
− | | |
− | *[http://onlinelibrary.wiley.com/doi/10.1111/gwmr.12028/full Removal of PCE DNAPL from Tight Clays using In Situ Thermal Desorption]<ref name="Heron2013">Heron, G., Lachance, J. and Baker, R., 2013. Removal of PCE DNAPL from tight clays using in situ thermal desorption. Groundwater Monitoring & Remediation, 33(4), 31-43. [http://onlinelibrary.wiley.com/doi/10.1111/gwmr.12028/full doi:10.1111/gwmr.12028]</ref>
| |
− | *[https://www.crcpress.com/Hazardous-and-Radioactive-Waste-Treatment-Technologies-Handbook/Oh/p/book/9780849395864 Thermal Conduction Heating for In-Situ Thermal Desorption of Soils.]<ref>Stegemeier, G.L. and Vinegar, H.J., 2001. Thermal conduction heating for in-situ thermal desorption of soils. In Chang H. Oh (ed.), Hazardous and Radioactive Waste Treatment Technol. Handbook, CRC Press, Boca Raton, FL. Chapter, 4, pgs. 1-37. ISBN 9780849395864.</ref>
| |
− | | |
− | ==Introduction==
| |
− | The principle of TCH is to use [[wikipedia: Thermal conduction | thermal conduction]] to distribute heat throughout the contaminated subsurface volume, raising the temperature high enough to mobilize and extract the chemicals. TCH treatment is commonly used at sites with significant contamination and a reason to clean up quickly. When the treatment zone is delineated well, and the TCH system designed and implemented with care, near complete removal of the contaminants is possible.
| |
− | | |
− | [[File:Heron ISTD Fig1.jpg|thumbnail|left|600 px|Figure 1. Thermal Conduction Heating (TCH) schematic.]]
| |
− | TCH sites have a heating system, which delivers the energy to the treatment volume, and an extraction and treatment system that pulls the contaminants and vapors out of the ground and then separates and treats the vapors and fluids (Fig. 1). The soil is heated by simple thermal conduction via heated metal pipes in the ground. Typical TCH systems utilize circuits of electrically powered heaters that are spaced systematically throughout the thermal treatment zone (TTZ) in a triangular pattern. Gas may also be used to heat the boreholes, requiring gas burners to be placed at each boring. The TCH technology is flexible in that it allows for a wide range of desired treatment temperatures based on the contaminants at the site.
| |
− | | |
− | [[wikipedia: Thermal conductivity |Thermal conductivity]] values for the entire range of known soils vary by a factor of < +/- 3, while fluid conductivity values of soils may vary by a factor of a million or more. Compared to fluid injection processes and other thermal technologies, the conductive heating process is more uniform in its vertical and horizontal sweep. Transport of the vaporized contaminants is further improved by increases in gas permeability, which results from drying of the soil close to the heaters<ref name="Heron2013" />. Preferential flow paths are created even in tight silt and clay layers, allowing flow and capture of the vaporized contaminants. Thermal conduction produces more uniform heat transfer through conduction and convection in the bulk of the soil volume, resulting in high contaminant removal efficiency<ref name="Heron2013" />.
| |
− | | |
− | Temperature and pressure monitoring wells are used to document performance of the heating and treatment (Fig. 1). Target temperatures are derived based on the contaminants of concern (COCs) and treatment goals.
| |
− | | |
− | TCH can be applied at low (<100°C), moderate (~100°C), and higher (>100°C) temperature levels to remediate a wide variety of contaminants, both above and below the water table. In order to heat to higher temperatures, pumping and/or vaporization must remove the naturally occurring pore and groundwater. In some instances, hydraulic barriers are used to facilitate dewatering prior to heating.
| |
− | | |
− | Before TCH treatment is considered complete, soil samples are typically collected and used to show that the remedial goals are met. Then, cool-down and site demobilization activities begin. If the interim sampling reveals areas with contamination above the project's criteria, system modifications and prolonged operation are used to reach the goals.
| |
− | | |
− | ==Applications==
| |
− | [[File:Heron ISTD Fig2.jpg|500px|thumbnail|left|Figure 2. Example use of TCH to treat a PCE source zone above and below the groundwater table<ref name="Heron2013" />. ]]
| |
− | Because TCH is based in simple heat conduction, it can be used above and below the water table. Temperatures above the boiling point of water are achievable for treating semi-volatile contaminants within the vadose zone<ref name="Baker2010">Baker, R.S., Bierschenk, J.M., LaChance, J., Heron, G., Phelan, D., and Clock, J.A., 2010. In situ thermal treatment of MGP waste and creosote. Paper H-057, in K.A. Fields and G.B. Wickramanayake (Chairs), Remediation of Chlorinated and Recalcitrant Compounds - 2010. Seventh International Conference on Remediation of Chlorinated and Recalcitrant Compounds, Monterey, CA. Battelle Memorial Institute, Columbus, OH.</ref>. TCH has been used routinely to treat volatiles such as [[wikipedia: Trichloroethylene | trichloroethylene (TCE)]] and [[wikipedia:Tetrachloroethylene|tetrachloroethene (PCE)]] as well<ref name="Heron2013" /><ref name="Heron2015">Heron, G., Parker, K., Fournier, S., Wood, P., Angyal, G., Levesque, J. and Villecca, R., 2015. World's Largest In Situ Thermal Desorption Project: Challenges and Solutions. Groundwater Monitoring & Remediation, 35(3), 89-100. [http://onlinelibrary.wiley.com/doi/10.1111/gwmr.12115/full doi: 10.1111/gwmr.12115]</ref><ref name="Heron2016">Heron, G., Bierschenk, J., Swift, R., Watson, R. and Kominek, M., 2016. Thermal DNAPL source zone treatment impact on a CVOC plume. Groundwater Monitoring & Remediation, 36(1), 26-37. [http://onlinelibrary.wiley.com/wol1/doi/10.1111/gwmr.12148/full doi: 10.1111/gwmr.12148]</ref>.
| |
− | | |
− | Example COCs include: [[Chlorinated Solvents |Chlorinated solvents]], [[wikipedia:Non-aqueous_phase_liquid|Non-aqueous phase liquids (NAPLs)]], [[wikipedia: Tar | Tar]], [[wikipedia: Polychlorinated biphenyl | Polychlorinated biphenyls (PCBs)]], [[Perfluoroalkyl and Polyfluoroalkyl Substances (PFAS)|Per- and polyfluoroalkyl substances (PFAS)]], [[wikipedia: Pesticide |Pesticides]], [[Polycyclic Aromatic Hydrocarbons (PAHs) | Polycyclic aromatic hydrocarbons (PAHs)]], [[wikipedia: Mercury (element) | Mercury]], Dioxins, [[Petroleum Hydrocarbons (PHCs)|Fuels and heavy hydrocarbons]], [[1,4-Dioxane]]
| |
− | | |
− | Target treatment temperatures are typically 90-100°C for volatile contaminants and between 150°C and 335°C for semi-volatile contaminants. Additionally, heating to 350°C and 400°C achieves a high degree of PFAS removal from soil. A typical application for volatile organics above and below the water table includes heating rods that flank the area of concern (Fig. 2). For chlorinated solvents, the target temperature is typically 100°C.
| |
− | | |
− | TCH is scalable and well-suited for large and deep sites, and when properly implemented it can lead to effective site closure<ref name="Heron2015" />. When combined with [[Thermal Remediation - Steam]], solutions are available for sites with substantial groundwater flow as well. TCH has also been proven effective for removal of dense non-aqueous phase liquid (DNAPL) in fractured rock<ref>Heron, G., Baker, R.S., Bierschenk, J.M., and LaChance, J., 2008. Use of thermal conduction heating for the remediation of DNAPL in fractured bedrock. Paper P-003, in: Bruce M. Sass (Conference Chair), Remediation of Chlorinated and Recalcitrant Compounds. Proceedings of the Sixth International Conference on Remediation of Chlorinated and Recalcitrant Compounds, Monterey, CA. Battelle Press, Columbus, OH.</ref>. When the treatment zone is properly delineated, and the thermal system implemented well, very high treatment efficiencies are achieved.
| |
− | | |
− | ==Case Studies==
| |
− | TCH has been used for sites with significant contamination and strong reasons to remediate. Examples are:
| |
− | [[File:Heron ISTD Fig3.jpg|500px|thumbnail|right|Figure 3. TCH well field for treatment of a 3.2-acre CVOC source zone. Electric power distribution equipment is seen in the foreground. An insulated vapor cover provides a vapor seal.]]
| |
− | | |
− | #Treatment of a 108-ft deep creosote spill at a site in northern Los Angeles, CA. The source zone was heated and treated at temperatures of 335°C. Residential remedial goals were met after removal of more than 1 million lbs or organics, and the client received a no further action letter that allowed unrestricted use of the property<ref name="Baker2010" />.
| |
− | #Remediation of a chlorinated solvent source area in tight clays beneath a building near the San Francisco Bay. TCH treatment took 110 days and target temperatures were 100°C. Removal of the mass and attainment of the soil standards allowed for redevelopment of the site<ref name="Heron2013" />.
| |
− | #A source zone beneath a former dry cleaner had led to a long-dissolved plume and vapor intrusion into homes. TCH was used to heat the source to 100°C, remove > 99.9% of the chlorinated solvents, and resulted in achievement of the remedial goals. The source treatment resulted in substantially reduced mass discharge into the dissolved plume. Five years after ISTD treatment, the client obtained permission to discontinue the pump and treat system<ref name="Heron2016" />.
| |
− | #Redevelopment of an industrial area near the Teterboro airport in New Jersey was only possible after treatment of a 3.2-acre chlorinated solvent source area. TCH was used to heat and treat the site, reaching the boiling point of water and the soil standards. Several challenges related to the large scale were identified and overcome, resulting in successful project completion<ref name="Heron2015" />. Figure 3 shows the large well field used to remove the DNAPL and meet remedial goals.
| |
− | | |
− | These case studies illustrate the type of sites addressed with TCH. Common themes are (1) significant source contamination and (2) a remediation driver that makes rapid site restoration attractive.
| |
− | | |
− | ==Summary==
| |
− | TCH can be effective for treating heavily contaminated source zones to low levels. The simplicity of the heating makes TCH a robust solution for complex sites, reducing uncertainties related to subsurface heterogeneity and properties. It can also be effective for treatment of semi-volatile organics that require temperatures above the boiling point of water, and for organic source zones in fractured rock.
| |
− | | |
− | ==References==
| |
− | | |
− | <references />
| |
− | | |
− | ==See Also==
| |